Ruud RA15AY Air Conditioners

Compare six carried RA15AY R-454B models with the LHP pressure-control option. Use full-model shop links, cabinet and electrical data, then establish the approved indoor equipment for the cooling quote.

  • R-454B
  • Single-stage scroll
  • 2–5-ton LHP models
  • 208/230 V single phase
Ruud RA15AY representative manufacturer product image
Ruud RA15AY representative manufacturer family image. Cabinet size and appearance vary by full model; use the actual drawing for the job.

Plan the equipment around the job

Keep the factory option in the model number.

The carried models below include the LHP suffix. Ruud lists these high/low-pressure-control variants separately from the base models, so keep the complete identifier through the quote and order.

01 / Full model

Retain the LHP suffix

Record the exact factory-option model shown in the chart and shop. The nominal size alone does not identify the ordered configuration.

02 / System rating

Quote the matched package

Ruud lists family efficiencies up to 16 SEER2 / 13 EER2. Establish the actual indoor coil or air handler and certified combination before assigning a rating to the job.

03 / Access and fit

Check the cabinet before the pad

The selected models range from 25 to 45 inches in operating height. Review the exact drawing, airflow/service clearances and piping route for the proposed location.

The numbers contractors need

RA15AY model specifications

Compare the listed full models, or select one for a focused view.

6 model references · confirm current sourcing and availability with Mar-Hy.

Ruud RA15AY model specifications
ReferenceRA15AY24AJ1NALHP2-ton · LHP optionRA15AY30AJ1NALHP2.5-ton · LHP optionRA15AY36AJ1NALHP3-ton · LHP optionRA15AY42AJ1NALHP3.5-ton · LHP optionRA15AY48AJ1NALHP4-ton · LHP optionRA15AY60AJ1NALHP5-ton · LHP option
Full outdoor modelRA15AY24AJ1NALHPRA15AY30AJ1NALHPRA15AY36AJ1NALHPRA15AY42AJ1NALHPRA15AY48AJ1NALHPRA15AY60AJ1NALHP
Nominal size: tons22.533.545
RefrigerantR-454BR-454BR-454BR-454BR-454BR-454B
Compressor operationSingle-stage scrollSingle-stage scrollSingle-stage scrollSingle-stage scrollSingle-stage scrollSingle-stage scroll
Factory optionLHP: high/low pressure controlLHP: high/low pressure controlLHP: high/low pressure controlLHP: high/low pressure controlLHP: high/low pressure controlLHP: high/low pressure control
Supply: V / phase / Hz208/230 / 1 / 60208/230 / 1 / 60208/230 / 1 / 60208/230 / 1 / 60208/230 / 1 / 60208/230 / 1 / 60
Minimum circuit ampacity: A131718203031
Maximum overcurrent protection: A202530305050
Operating height: in.252731353545
Operating length: in.33.7533.7533.7533.7533.7535.75
Operating width: in.33.7533.7533.7533.7533.7535.75
Operating weight: lb178190210252243266
Liquid valve connection O.D.: in.3/83/83/83/83/83/8
Suction valve connection O.D.: in.3/43/43/47/87/87/8

Source: RA15AY specification sheet: model identification p.4, electrical data p.5, operating dimensions p.7. Reviewed November 11, 2026.

  • Use the full model, electrical phase and equipment nameplate. MCA and overcurrent values are manufacturer references; installation and conductor/protection selection must follow the applicable manufacturer instructions and requirements.
  • The listed models are equipment references supported by dated carried-model records, not a live inventory feed. Confirm current availability and contractor pricing before ordering.
  • The current A22-347 Rev. 4 model-identification table lists all six selected LHP models. General dimensions and electrical values are taken from the matching capacity and single-phase rows.

“Up to 16 SEER2” is a family limit, not every model’s rating.

The manufacturer specification lists RA15AY efficiencies up to 16 SEER2 / 13 EER2. The actual equipment combination, airflow and installation determine the applicable listed reference; preserve the full LHP model and indoor-unit identity when checking AHRI.

Search by the full outdoor model, then verify every listed component and the current official certificate. A matching brand or nominal size is not an approved system.

Read it. Save it. Bring it to the job.

RA15AY equipment literature

Open the manufacturer reference you need. Documents load when selected.

Search RA15AY references in the Mar-Hy document library

Documents are linked directly and open only when selected. Check the model, revision and complete system scope before applying technical values.

Get a useful quote on the first conversation

Bring the complete cooling-system request.

  1. Full outdoor model, including electrical phase and factory option suffix.
  2. Indoor coil or air-handler model, refrigerant/metering arrangement and required controls.
  3. Cooling load, design conditions, airflow and duct-system requirements.
  4. Cabinet location, service and airflow clearances, piping route and electrical supply.
  5. Required accessories, job schedule and the complete equipment list for contractor pricing.

Selection questions

Does the family efficiency apply to every indoor combination?

Use the current certified record for the exact equipment package. The indoor unit, airflow and controls affect the listed capacity and efficiency.

Does a model listed here mean it is in stock today?

Confirm current sourcing, availability and contractor pricing through the shop or Mar-Hy before committing to the job.

Find it at Mar-Hy

Price the equipment. Plan the whole job.

Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.