Skip to main content

Call Us: Oregon and SW Washington: (503) 353-0100: Contact Us | Business Hours: 7:00 AM to 5:00 PM Mon-Fri

Friedrich / Contractor equipment reference

Friedrich Floating Air Select Heat Pumps

Start with the inventory-backed FSHSR36B3D R-32 outdoor reference and its listed FAHSW36A3D indoor unit. Review the actual rated pair data and source documents.

  • R-32
  • Single-zone wall-mounted
  • FSHSR36B3D reference
Friedrich Floating Air Select representative manufacturer product image
Friedrich Floating Air Select representative manufacturer family image. Appearance does not establish an approved equipment combination.

Plan the equipment around the job

The model class and the rated output are different numbers.

The selected model is a 36,000 Btu/h class reference. The manufacturer table lists 34,600 Btu/h cooling at 95°F and 35,000 Btu/h heating at 47°F for the listed pair.

01 / Capacity

Use the rated pair data

Compare the room load and design conditions with the actual selected system performance, including the required low-temperature heating data.

02 / Indoor unit

Keep FAHSW36A3D in the quote

The indoor model is part of this listed reference. Confirm the applicable controls, wall space, installation scope and condensate arrangement.

03 / Family scope

Confirm additional Select sizes separately

The brochure includes other capacities. This reference focuses on the full model with positive dated inventory evidence; it does not certify the complete active assortment.

The numbers contractors need

Floating Air Select model specifications

Full-model reference for the listed equipment configuration.

1 model reference · confirm current sourcing and availability with Mar-Hy.

Friedrich Floating Air Select model specifications
ReferenceFSHSR36B3D36,000 Btu/h model class
Outdoor modelFSHSR36B3D
Listed indoor modelFAHSW36A3D
Model capacity class: Btu/h36,000
RefrigerantR-32
Power: V / phase / Hz208/230 / 1 / 60
Listed pair cooling @ 95°F: Btu/h34,600
Listed pair heating @ 47°F: Btu/h35,000

Source: Floating Air Select submittal, page 2; Floating Air brochure, page 9. Reviewed November 11, 2026.

  • Use the full model suffix and the cited document revision. Confirm current sourcing with Mar-Hy; these model references are not live availability.
  • The listed equipment does not establish an approved combination by shared capacity alone.
  • The cited submittal table and dimensional drawing disagree on the outdoor width. Dimension and electrical-protection rows are omitted pending exact revision/nameplate confirmation.

Rate the complete equipment combination.

The performance values apply to the manufacturer-listed FSHSR36B3D / FAHSW36A3D pair. Confirm the current certified record and the actual application before using them for an incentive or design claim.

Manufacturer-listed system references · cited brochure pairs
ReferenceFSHSR36B3D36,000 Btu/h model class
Listed pair SEER220
Listed pair HSPF28.4

Read it. Save it. Bring it to the job.

Floating Air Select equipment literature

Open the manufacturer reference you need. Documents load when selected.

Search Floating Air Select references in the Mar-Hy document library

Check the full model, revision and system scope before using technical information. Open the selected document when needed.

Get a useful quote on the first conversation

Bring the complete equipment request.

  1. Full outdoor and indoor model numbers, or the existing equipment identification.
  2. Load calculation, heating design conditions and proposed equipment locations.
  3. Available electrical supply, required controls and relevant installation constraints.
  4. Piping route, condensate plan and the accessories needed to complete the work.
  5. Project schedule; request current contractor pricing and availability for the complete package.

Selection questions

Do these models have the same system efficiency?

No. Use the complete listed equipment combination and its certified ratings. Do not assign a family maximum to every model or indoor pairing.

Does a listed model mean it is available now?

These are equipment references. Confirm current contractor pricing, sourcing and availability with Mar-Hy before committing to the job.

Where should I start the selection?

Start with the load and application, then use the full model numbers and manufacturer documents to establish the equipment and required accessories.

Find it at Mar-Hy

Price the equipment. Plan the whole job.

Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.