Daikin AURORA wall-mounted Heat Pumps

Compare selected R-32 AURORA wall-mounted references, their listed indoor units and manufacturer dimensions. Keep this generation separate from older AURORA equipment.

  • R-32
  • Single-zone wall-mounted
  • Full model pairs below
Daikin AURORA wall-mounted representative manufacturer product image
Daikin AURORA wall-mounted representative manufacturer family image. Appearance does not establish an approved equipment combination.

Plan the equipment around the job

Use the actual heating conditions when selecting an AURORA proposal.

Use the manufacturer-listed indoor/outdoor references and the full installation scope to prepare the equipment package. The table is a model reference, not a complete design.

01 / Heating selection

Bring the design temperature

Use manufacturer heating data for the actual outdoor condition and the selected pair. A nominal model size is not the delivered heating output at every temperature.

02 / Matched equipment

Keep RXT and FTXV references together

The brochure lists specific indoor/outdoor combinations. Use the full model suffix, refrigerant and applicable manufacturer selection data for the proposal.

03 / Installation

Plan the mounting and winter conditions

Check outdoor placement, piping, condensate and the accessories required by the exact installation instructions. Include these items in the equipment quote.

The numbers contractors need

AURORA wall-mounted model specifications

Compare the listed full models, or select one for a focused view.

3 model references · confirm current sourcing and availability with Mar-Hy.

Daikin AURORA wall-mounted model specifications
ReferenceRXT09AVJU99,000 Btu/h classRXT12AVJU912,000 Btu/h classRXT18AVJU918,000 Btu/h class
Outdoor modelRXT09AVJU9RXT12AVJU9RXT18AVJU9
Listed indoor modelFTXV09AVJU9FTXV12AVJU9FTXV18AVJU9
Model capacity class: Btu/h9,00012,00018,000
RefrigerantR-32R-32R-32
Outdoor dimensions H × W × D: in.21-15/16 × 26-9/16 × 11-3/1621-15/16 × 26-9/16 × 11-3/1629-1/2 × 34-1/4 × 12-5/8
Indoor dimensions H × W × D: in.11-1/4 × 30-5/16 × 8-3/411-1/4 × 30-5/16 × 8-3/411-5/8 × 39 × 10-3/8

Source: Manufacturer brochure, printed page 8. Reviewed November 11, 2026.

  • Use the full model suffix and the cited document revision. Confirm current sourcing with Mar-Hy; these model references are not live availability.
  • The listed equipment does not establish an approved combination by shared capacity alone.
  • Dimensions are transcribed from the cited brochure. Refer to the manufacturer dimensional drawing and installation clearances for the actual model.

Use the rating and heating data for the listed pair.

The capacity-class row identifies the model class. It is not a rated-output claim. Confirm the pair’s rated and design-condition capacity, efficiency and applicable AHRI record before using performance figures in a proposal.

Read it. Save it. Bring it to the job.

AURORA wall-mounted equipment literature

Open the manufacturer reference you need. Documents load when selected.

Search AURORA wall-mounted references in the Mar-Hy document library

This manufacturer brochure includes the cited technical table. A separate full-model submittal is not linked in this reference; use the manufacturer selection resources and confirm the exact equipment documents with Mar-Hy.

Get a useful quote on the first conversation

Bring the complete equipment request.

  1. Full outdoor and indoor model numbers, or the existing equipment identification.
  2. Load calculation, heating design conditions and proposed equipment locations.
  3. Available electrical supply, required controls and relevant installation constraints.
  4. Piping route, condensate plan and the accessories needed to complete the work.
  5. Project schedule; request current contractor pricing and availability for the complete package.

Selection questions

Do these models have the same system efficiency?

No. Use the complete listed equipment combination and its certified ratings. Do not assign a family maximum to every model or indoor pairing.

Does a listed model mean it is available now?

These are equipment references. Confirm current contractor pricing, sourcing and availability with Mar-Hy before committing to the job.

Where should I start the selection?

Start with the load and application, then use the full model numbers and manufacturer documents to establish the equipment and required accessories.

Find it at Mar-Hy

Price the equipment. Plan the whole job.

Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.