Skip to main content

Call Us: Oregon and SW Washington: (503) 353-0100: Contact Us | Business Hours: 7:00 AM to 5:00 PM Mon-Fri

Gibson / Contractor equipment reference

Gibson KG7TC Gas Furnaces

A contractor reference for the 95% AFUE, two-stage upflow/horizontal furnace family, with full-model specifications and manufacturer literature.

  • 95% AFUE reference
  • Two-stage gas heat
  • Upflow / horizontal
Gibson KG7TC representative manufacturer product image
KG7TC manufacturer specification image. Match the full model, revision and installation orientation; illustration is representative family artwork.

Plan the equipment around the job

Select heating input and airflow as separate job requirements.

A furnace quote needs more than the high-fire input number. Confirm the load, cabinet fit, available airflow, venting route and any paired cooling coil before selecting the complete KG7TC model.

01 / Heating stages

Keep input and output distinct

The specifications publish high- and low-stage gas input separately from heating output. Use the proper figure for the question being answered; AFUE is a seasonal efficiency rating, not an instruction to estimate every operating output.

02 / Blower selection

Check the actual airflow table

The cooling-airflow code identifies a selection range, not the airflow delivered at every static pressure. Check the exact blower configuration and manufacturer table for the coil, ducts and required operating mode.

03 / Changeout scope

Measure more than cabinet width

Verify height, depth, supply/return transitions, service space, venting, combustion-air provisions and condensate routing. Those job details can change the materials and installation scope even when the furnace width looks familiar.

The numbers contractors need

KG7TC model specifications

Compare the listed full models, or select one for a focused view.

2 model references · confirm current sourcing and availability with Mar-Hy.

Gibson KG7TC model specifications
ReferenceKG7TC-060D-E24BP60,000 Btu/h high-fire inputKG7TC-080D-E35CP80,000 Btu/h high-fire input
Furnace modelKG7TC-060D-E24BPKG7TC-080D-E35CP
Heating stagesTwoTwo
AFUE (%)9595
Gas input — high / low (Btu/h)60,000 / 39,00080,000 / 52,000
Heating output — high / low (Btu/h)57,000 / 37,00076,000 / 49,000
Power supply in specification120 V · 60 Hz120 V · 60 Hz
Cabinet H × W × D (in.)34-1/2 × 17-1/2 × 2834-1/2 × 21 × 28
Blower motor H.P. / type1/2 · BLDC / ECM3/4 · BLDC / ECM
Motor full-load amps in reference6.48.8
Rated external static pressure (in. w.c.)0.500.50
Listed temperature-rise range (°F)30–6035–65
Shipping weight (lb)120130
Gas connection1/2 in. N.P.T.1/2 in. N.P.T.

Source: Gibson / Nortek 468F-0725 — pages 3–4, dimensions and specifications. Reviewed November 10, 2026.

  • The specification table uses model patterns ending in an asterisk; the manufacturer model references identify the listed BP/CP models. Preserve the full model and revision during selection.
  • Published input ratings apply under the source document’s stated conditions. Altitude and fuel applications require the applicable manufacturer procedure.
  • Motor FLA is not the furnace’s branch-circuit sizing instruction. Use the nameplate and installation instructions for electrical selection.
  • The external-static reference is not a guarantee of airflow at a selected speed. Use the exact blower table and equipment configuration.

A furnace rating does not approve the entire cooling system.

The 95% AFUE figure describes the furnace’s listed heating-efficiency reference. A paired air conditioner or heat pump has its own complete-system rating. If the job includes cooling or dual fuel, confirm the outdoor unit, indoor coil and furnace combination separately and use the official AHRI record where applicable.

Get a useful quote on the first conversation

Make the furnace quote installation-ready.

  1. Required heating capacity and complete replacement model, including revision.
  2. Furnace orientation, cabinet width and planned supply/return transitions.
  3. Paired coil and outdoor-unit models, required airflow and blower configuration.
  4. Fuel, altitude, venting, combustion air and condensate requirements.
  5. Controls, accessories, warranty paperwork and the job’s delivery schedule.

Selection questions

Is 60,000 Btu/h the heat delivered to the duct system?

It is the high-fire gas input for the listed 060 model. The manufacturer separately lists 57,000 Btu/h high-stage heating output under its stated rating conditions. Preserve that distinction when quoting or comparing equipment.

Does the blower code guarantee a certain cooling tonnage?

No. It is a selection identifier. Actual delivered airflow depends on the speed/configuration and external static pressure; use the manufacturer’s matching blower table and the system requirements.

Can the same literature be used for a different KG7 suffix?

Only when the document’s scope includes that complete model and revision. This chart covers KG7TC, not an automatic substitution for KG7SK or KG7TN references.

Find it at Mar-Hy

Price the equipment. Plan the whole job.

Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.