ADP mFurnace Electric Furnaces

Plan the manufactured-home furnace, coil cabinet and electric-heat requirements as separate selections. Start with the confirmed AMHE3D10B2N1 reference below.

  • Manufactured-home application
  • 5-speed ECM
  • Separate coil cabinet
ADP mFurnace representative manufacturer product image
ADP mFurnace family image shown with a coil cabinet. The N cabinet code in AMHE3D10B2N1 means the coil cabinet is not included.

Plan the equipment around the job

Build the furnace and coil-cabinet package deliberately.

The mFurnace is an electric-furnace and blower platform for manufactured-home applications. Its unit-size code, electric-heat option and separate coil cabinet answer different selection questions; none should be inferred from the overall product photo.

01 / Full model identification

Read every part of the code

AMHE3D10B2N1 identifies the ECM blower, size-3 platform, downflow configuration, nominal 10 kW heat option, breaker connection, 208/240 V supply code and no included coil cabinet. Keep that complete identity on the order.

02 / Cabinet and coil

Separate the furnace from the enclosure

The furnace cabinet and an MH-series coil cabinet have separate dimensions and model numbers. Choose the cabinet and evaporator coil for the actual installation rather than treating MHCDLS23 or a similar cabinet reference as the furnace model.

03 / Airflow and heat

Use the correct operating conditions

Published nominal airflow is not the delivered airflow at every speed and static pressure. Electric-heat output and electrical values also change with supply voltage. Use the matching tables for the selected configuration.

The numbers contractors need

mFurnace model specifications

Full-model reference for the confirmed furnace configuration.

1 model reference · confirm current sourcing and availability with Mar-Hy.

ADP mFurnace model specifications
ReferenceAMHE3D10B2N1Size-3 ECM · nominal 10 kW at 240 V
Full furnace modelAMHE3D10B2N1
ApplicationManufactured-home electric furnace
Unit-size code3 · size-3 blower platform
Blower motor5-speed ECM
Factory configurationDownflow; field-conversion requirements apply
Supply-voltage code208/240 V · 1 phase · 60 Hz
Electric-heat code10 · nominal 10 kW at 240 V
Line-voltage connection codeB · circuit breaker
Coil-cabinet codeN · cabinet not included
Furnace H × W × D (in.)33.0 × 19.8 × 23.4 — specification drawing
Nominal family airflow reference (CFM)900–1,100; actual airflow depends on tap and static
Transformer reference40 VA · Class 2

Source: ADP SG-AMAH-01-02 — pages 2, 4, 6 and 9. Reviewed November 10, 2026.

  • The complete model is drawn from the existing public carried-model reference; it is not a claim of current stock.
  • The separate sales guide rounds furnace depth to 23.5 inches; the chart preserves the 23.4-inch dimension shown in the specification drawing. Check the actual installation dimensions.
  • Airflow must be taken from the correct tap, static-pressure and equipment-configuration table. A size code is not a heat-pump system capacity or efficiency rating.
  • Separate coil cases and evaporator coils are additional selections. This reference does not resolve other ADP coil-series or RG-model applicability questions.

Keep 208 V and 240 V electric-heat data separate.

For the size-3 platform with the 10 kW heat option, the cited specification provides different electrical values at 208 V and 240 V. These are manufacturer table references, not a branch-circuit design. Verify the actual nameplate, heater configuration, supplied breaker and applicable instructions before installation.

Size-3 platform with nominal 10 kW heat option · ADP specification page 9
Reference condition208 V240 V
Nominal heat at stated voltage (kW)7.51 — source correction factor applied10.0
Total current in source table (A)40.045.6
Minimum circuit ampacity in source table (A)50.057.0
Maximum circuit breaker in source table (A)5060

For a heat-pump or cooling-system rating, search the complete outdoor-unit and coil combination. The furnace’s electric-heat and blower data do not establish an AHRI system rating.

Get a useful quote on the first conversation

Order the furnace and the missing pieces together.

  1. Complete furnace model, actual supply voltage and required electric-heat option.
  2. Existing installation orientation, furnace footprint and permitted conversion requirements.
  3. The separate coil cabinet, evaporator coil and outdoor-unit models where applicable.
  4. Required airflow, duct/static conditions, thermostat and electrical nameplate requirements.
  5. Accessories, warranty documents and current pricing, sourcing and delivery timing.

Selection questions

Does the pictured coil cabinet come with AMHE3D10B2N1?

No. The N cabinet code identifies no included coil cabinet. Select the cabinet and evaporator coil separately for the actual installation; the family photo illustrates one assembled arrangement.

Is the 10 kW option 10 kW at every supply voltage?

No. The manufacturer rates that option at 240 V and gives a 0.751 output correction factor for 208 V. Use the voltage-specific electrical table and the actual equipment nameplate.

Does the blower’s size-3 code establish a complete 3-ton heat-pump system?

No. Confirm required airflow and the actual blower configuration, coil and outdoor equipment. Use the complete approved combination to establish cooling/heating capacity and system ratings.

Find it at Mar-Hy

Price the equipment. Plan the whole job.

Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.

Size-3 ECM · nominal 10 kW at 240 V

AMHE3D10B2N1

Look up model in the shop

Confirm current price and availability in the store.