Verify the exact coil and metering
The specification sheet lists designated tested combinations. Confirm the actual coil suffix, approved metering and current certified record for the equipment you intend to supply.
Call Us: Oregon and SW Washington: (503) 353-0100: Contact Us | Business Hours: 7:00 AM to 5:00 PM Mon-Fri
Gibson / Contractor equipment reference
Build a practical cooling quote around three carried Gibson WSA4BD R-454B models. Compare electrical requirements and cabinet dimensions, then check the manufacturer-listed indoor-coil and performance references.


Plan the equipment around the job
WSA4BD is a single-stage scroll air-conditioner family. Selecting the outdoor nominal size is the beginning of the job; the coil, metering arrangement, airflow and refrigerant application complete the system plan.
The specification sheet lists designated tested combinations. Confirm the actual coil suffix, approved metering and current certified record for the equipment you intend to supply.
The selected2-ton unit has a smaller footprint than the2.5- and3-ton references. Circuit ampacity and maximum fuse values also change by model; keep those details in the quote.
Manufacturer suction-line guidance changes with model and run length and includes reducer notes. Review that table and the installation instructions for the actual piping route.
The numbers contractors need
Compare the listed full models, or select one for a focused view.
3 model references · confirm current sourcing and availability with Mar-Hy.
| Reference | WSA4BD5M1SN24K2-ton nominal | WSA4BD5M1SN30K2.5-ton nominal | WSA4BD5M1SN36K3-ton nominal |
|---|---|---|---|
| Full outdoor model | WSA4BD5M1SN24K | WSA4BD5M1SN30K | WSA4BD5M1SN36K |
| Nominal size: tons | 2 | 2.5 | 3 |
| Refrigerant | R-454B | R-454B | R-454B |
| Compressor operation | Single-stage scroll | Single-stage scroll | Single-stage scroll |
| Supply: V / phase / Hz | 208/230 / 1 / 60 | 208/230 / 1 / 60 | 208/230 / 1 / 60 |
| Minimum circuit ampacity: A | 13.2 | 16.8 | 18.3 |
| Maximum delay fuse: A | 20 | 25 | 30 |
| Cabinet height: in. | 27 | 27 | 27 |
| Cabinet width: in. | 22.75 | 31 | 31 |
| Cabinet depth: in. | 22.75 | 31 | 31 |
| Approximate shipping weight: lb | 130 | 161 | 168 |
| Manufacturer sound rating: dBA | 72 | 73 | 79 |
Source: WSA4BD007G-1024: nomenclature/dimensions p.2, electrical data p.3, designated combinations p.4. Reviewed November 11, 2026.
Review the manufacturer’s listed indoor-coil combinations, cooling capacity and efficiency below. Confirm the specified coil, time-delay relay and current AHRI certificate when selecting the complete system.
| Reference | WSA4BD5M1SN24K2-ton nominal | WSA4BD5M1SN30K2.5-ton nominal | WSA4BD5M1SN36K3-ton nominal |
|---|---|---|---|
| Manufacturer-listed indoor coil | C75BHM02430C-A | C75BHM02430C-A | C75BHM03642C-B |
| Listed pair cooling capacity: Btu/h | 23,000 | 28,600 | 34,800 |
| Listed pair SEER2 | 13.4 | 13.4 | 13.4 |
| Listed pair EER2 | 11.0 | 11.0 | 11.0 |
| Listed pair indoor airflow: CFM | 700 | 875 | 1,050 |
Search by the full outdoor model, then verify every listed component and the current official certificate. A matching brand or nominal size is not an approved system.
Read it. Save it. Bring it to the job.
Open the manufacturer reference you need. Documents load when selected.
Search WSA4BD references in the Mar-Hy document library
Documents are linked directly and open only when selected. Check the model, revision and complete system scope before applying technical values.
Get a useful quote on the first conversation
Use the current certified record for the exact equipment package. The indoor unit, airflow and controls affect the listed capacity and efficiency.
Confirm current sourcing, availability and contractor pricing through the shop or Mar-Hy before committing to the job.
Find it at Mar-Hy
Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.
WSA4BD5M1SN24K
Look up model in the shopConfirm current price and availability in the store.
Find this model’s AHRI referencesWSA4BD5M1SN30K
Look up model in the shopConfirm current price and availability in the store.
Find this model’s AHRI referencesWSA4BD5M1SN36K
Look up model in the shopConfirm current price and availability in the store.
Find this model’s AHRI referencesFind WSA4BD equipment documents
Explore Gibson equipment through Mar-Hy
View Mar-Hy contractor training
Prepared for HVAC contractors and trade purchasers. Match the complete model, revision, installation and system combination. This reference is not a live stock feed or a guarantee of design suitability, warranty eligibility or incentive qualification. Follow the applicable manufacturer instructions for the actual equipment.