Ruud / Contractor equipment reference

Ruud RA15AZ Air Conditioners

Keep the carried RA15AZ24AJ3CA R-410A reference separate from the R-454B RA15AY family. Review the communicating-control approach, installation data and manufacturer documents before planning the complete system.

  • R-410A
  • 2-ton reference
  • Variable-speed twin rotary
  • EcoNet enabled
Ruud RA15AZ representative manufacturer product image
Ruud RA15AZ representative manufacturer family image. Cabinet size and appearance vary by full model; use the actual drawing for the job.

Plan the equipment around the job

The controls are part of the RA15AZ equipment selection.

RA15AZ uses a variable-speed twin-rotary compressor with an inverter drive. The selected thermostat/control arrangement determines how the system operates, so specify it with the indoor equipment.

01 / Control approach

Plan EcoNet with the system

The manufacturer describes variable-speed operation with an EcoNet Smart Thermostat and three-speed operation with a two-stage24V thermostat. Confirm the applicable controls and indoor combination.

02 / Refrigerant generation

Keep the R-410A reference distinct

RA15AZ and RA15AY are different equipment families. This selected RA15AZ model is an R-410A reference; follow the actual equipment and manufacturer application requirements.

03 / Focused model scope

Check the exact2-ton unit

This page focuses on the full model supported by the saved carried-equipment record. Other RA15AZ capacities require their own sourcing and exact-model confirmation.

The numbers contractors need

RA15AZ model specifications

Full-model reference for the selected air-conditioner configuration.

1 model reference · confirm current sourcing and availability with Mar-Hy.

Ruud RA15AZ model specifications
ReferenceRA15AZ24AJ3CA2-ton · communicating reference
Full outdoor modelRA15AZ24AJ3CA
Nominal size: tons2
RefrigerantR-410A
CompressorVariable-speed twin rotary
Supply: V / phase / Hz208/230 / 1 / 60
Minimum circuit ampacity: A12
Maximum overcurrent protection: A20
Operating height: in.27
Operating length: in.29.75
Operating width: in.29.75
Operating weight: lb167
Liquid valve connection O.D.: in.3/8
Suction valve connection O.D.: in.3/4

Source: RA15AZ specification sheet: model identification p.4, electrical data p.5, operating dimensions p.7. Reviewed November 11, 2026.

  • Use the full model, electrical phase and equipment nameplate. MCA and overcurrent values are manufacturer references; installation and conductor/protection selection must follow the applicable manufacturer instructions and requirements.
  • The listed models are equipment references supported by dated carried-model records, not a live inventory feed. Confirm current availability and contractor pricing before ordering.

Confirm the indoor match and control-dependent operation.

Ruud lists RA15AZ family efficiencies up to15.2 SEER2 / 9.8 EER2. Use the actual listed equipment and control arrangement for the quote, and confirm the current certified combination rather than treating the outdoor unit as a complete rated system.

Search by the full outdoor model, then verify every listed component and the current official certificate. A matching brand or nominal size is not an approved system.

Read it. Save it. Bring it to the job.

RA15AZ equipment literature

Open the manufacturer reference you need. Documents load when selected.

Search RA15AZ references in the Mar-Hy document library

Documents are linked directly and open only when selected. Check the model, revision and complete system scope before applying technical values.

Get a useful quote on the first conversation

Bring the complete cooling-system request.

  1. Full outdoor model, including electrical phase and factory option suffix.
  2. Indoor coil or air-handler model, refrigerant/metering arrangement and required controls.
  3. Cooling load, design conditions, airflow and duct-system requirements.
  4. Cabinet location, service and airflow clearances, piping route and electrical supply.
  5. Required accessories, job schedule and the complete equipment list for contractor pricing.

Selection questions

Does RA15AZ require a particular thermostat?

Use the manufacturer control instructions for the exact system. The cited brochure distinguishes variable-speed operation with EcoNet from three-speed operation with a two-stage24V thermostat.

Does the family efficiency apply to every indoor combination?

Use the current certified record for the exact equipment package. The indoor unit, airflow and controls affect the listed capacity and efficiency.

Does a model listed here mean it is in stock today?

Confirm current sourcing, availability and contractor pricing through the shop or Mar-Hy before committing to the job.