Retain the LHP suffix
Record the exact factory-option model shown in the chart and shop. The nominal size alone does not identify the ordered configuration.
Call Us: Oregon and SW Washington: (503) 353-0100: Contact Us | Business Hours: 7:00 AM to 5:00 PM Mon-Fri
Ruud / Contractor equipment reference
Compare six carried RA15AY R-454B models with the LHP pressure-control option. Use full-model shop links, cabinet and electrical data, then establish the approved indoor equipment for the cooling quote.


Plan the equipment around the job
The carried models below include the LHP suffix. Ruud lists these high/low-pressure-control variants separately from the base models, so keep the complete identifier through the quote and order.
Record the exact factory-option model shown in the chart and shop. The nominal size alone does not identify the ordered configuration.
Ruud lists family efficiencies up to 16 SEER2 / 13 EER2. Establish the actual indoor coil or air handler and certified combination before assigning a rating to the job.
The selected models range from 25 to 45 inches in operating height. Review the exact drawing, airflow/service clearances and piping route for the proposed location.
The numbers contractors need
Compare the listed full models, or select one for a focused view.
6 model references · confirm current sourcing and availability with Mar-Hy.
| Reference | RA15AY24AJ1NALHP2-ton · LHP option | RA15AY30AJ1NALHP2.5-ton · LHP option | RA15AY36AJ1NALHP3-ton · LHP option | RA15AY42AJ1NALHP3.5-ton · LHP option | RA15AY48AJ1NALHP4-ton · LHP option | RA15AY60AJ1NALHP5-ton · LHP option |
|---|---|---|---|---|---|---|
| Full outdoor model | RA15AY24AJ1NALHP | RA15AY30AJ1NALHP | RA15AY36AJ1NALHP | RA15AY42AJ1NALHP | RA15AY48AJ1NALHP | RA15AY60AJ1NALHP |
| Nominal size: tons | 2 | 2.5 | 3 | 3.5 | 4 | 5 |
| Refrigerant | R-454B | R-454B | R-454B | R-454B | R-454B | R-454B |
| Compressor operation | Single-stage scroll | Single-stage scroll | Single-stage scroll | Single-stage scroll | Single-stage scroll | Single-stage scroll |
| Factory option | LHP: high/low pressure control | LHP: high/low pressure control | LHP: high/low pressure control | LHP: high/low pressure control | LHP: high/low pressure control | LHP: high/low pressure control |
| Supply: V / phase / Hz | 208/230 / 1 / 60 | 208/230 / 1 / 60 | 208/230 / 1 / 60 | 208/230 / 1 / 60 | 208/230 / 1 / 60 | 208/230 / 1 / 60 |
| Minimum circuit ampacity: A | 13 | 17 | 18 | 20 | 30 | 31 |
| Maximum overcurrent protection: A | 20 | 25 | 30 | 30 | 50 | 50 |
| Operating height: in. | 25 | 27 | 31 | 35 | 35 | 45 |
| Operating length: in. | 33.75 | 33.75 | 33.75 | 33.75 | 33.75 | 35.75 |
| Operating width: in. | 33.75 | 33.75 | 33.75 | 33.75 | 33.75 | 35.75 |
| Operating weight: lb | 178 | 190 | 210 | 252 | 243 | 266 |
| Liquid valve connection O.D.: in. | 3/8 | 3/8 | 3/8 | 3/8 | 3/8 | 3/8 |
| Suction valve connection O.D.: in. | 3/4 | 3/4 | 3/4 | 7/8 | 7/8 | 7/8 |
Source: RA15AY specification sheet: model identification p.4, electrical data p.5, operating dimensions p.7. Reviewed November 11, 2026.
The manufacturer specification lists RA15AY efficiencies up to 16 SEER2 / 13 EER2. The actual equipment combination, airflow and installation determine the applicable listed reference; preserve the full LHP model and indoor-unit identity when checking AHRI.
Search by the full outdoor model, then verify every listed component and the current official certificate. A matching brand or nominal size is not an approved system.
Read it. Save it. Bring it to the job.
Open the manufacturer reference you need. Documents load when selected.
Search RA15AY references in the Mar-Hy document library
Documents are linked directly and open only when selected. Check the model, revision and complete system scope before applying technical values.
Get a useful quote on the first conversation
Use the current certified record for the exact equipment package. The indoor unit, airflow and controls affect the listed capacity and efficiency.
Confirm current sourcing, availability and contractor pricing through the shop or Mar-Hy before committing to the job.
Find it at Mar-Hy
Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.
RA15AY24AJ1NALHP
Look up model in the shopConfirm current price and availability in the store.
Find this model’s AHRI referencesRA15AY30AJ1NALHP
Look up model in the shopConfirm current price and availability in the store.
Find this model’s AHRI referencesRA15AY36AJ1NALHP
Look up model in the shopConfirm current price and availability in the store.
Find this model’s AHRI referencesRA15AY42AJ1NALHP
Look up model in the shopConfirm current price and availability in the store.
Find this model’s AHRI referencesRA15AY48AJ1NALHP
Look up model in the shopConfirm current price and availability in the store.
Find this model’s AHRI referencesRA15AY60AJ1NALHP
Look up model in the shopConfirm current price and availability in the store.
Find this model’s AHRI referencesFind RA15AY equipment documents
Explore Ruud equipment through Mar-Hy
View Mar-Hy contractor training
Prepared for HVAC contractors and trade purchasers. Match the complete model, revision, installation and system combination. This reference is not a live stock feed or a guarantee of design suitability, warranty eligibility or incentive qualification. Follow the applicable manufacturer instructions for the actual equipment.