Ruud RA13NY Air Conditioners

Compare carried RA13NY R-454B air conditioners across nominal sizes and electrical variants. Keep the single-phase and three-phase models distinct while planning the indoor match, electrical scope and installation space.

  • R-454B
  • Single-stage scroll
  • 1.5–5-ton references
  • 1- and 3-phase models
Ruud RA13NY representative manufacturer product image
Ruud RA13NY representative manufacturer family image. Cabinet size and appearance vary by full model; use the actual drawing for the job.

Plan the equipment around the job

Choose the electrical variant with the cooling size.

Two RA13NY units with the same nominal tonnage can require different electrical service. Use the full model and the correct electrical row before putting equipment into the quote.

01 / Power supply

Separate AJ1 and AC1 models

This chart includes 208/230 V single-phase models and selected three-phase models. Confirm the available supply and full suffix before comparing circuit requirements.

02 / Indoor equipment

Build the R-454B system together

Identify an approved indoor coil or air handler, metering device and applicable refrigerant-detection provisions. An existing R-410A coil is not approved by a similar nominal size alone.

03 / Installation space

Measure cabinet and clearances

Cabinet height changes substantially across this family. Include the manufacturer service and discharge clearances, piping access and outdoor support in the installation plan.

The numbers contractors need

RA13NY model specifications

Compare the listed full models, or select one for a focused view.

9 model references · confirm current sourcing and availability with Mar-Hy.

Ruud RA13NY model specifications
ReferenceRA13NY18AJ1NA1.5-ton · 1-phaseRA13NY24AJ1NA2-ton · 1-phaseRA13NY30AJ1NA2.5-ton · 1-phaseRA13NY36AC1NA3-ton · 3-phaseRA13NY36AJ1NA3-ton · 1-phaseRA13NY42AJ1NA3.5-ton · 1-phaseRA13NY48AC1NA4-ton · 3-phaseRA13NY48AJ1NA4-ton · 1-phaseRA13NY60AJ1NA5-ton · 1-phase
Full outdoor modelRA13NY18AJ1NARA13NY24AJ1NARA13NY30AJ1NARA13NY36AC1NARA13NY36AJ1NARA13NY42AJ1NARA13NY48AC1NARA13NY48AJ1NARA13NY60AJ1NA
Nominal size: tons1.522.5333.5445
RefrigerantR-454BR-454BR-454BR-454BR-454BR-454BR-454BR-454BR-454B
Compressor operationSingle-stage scrollSingle-stage scrollSingle-stage scrollSingle-stage scrollSingle-stage scrollSingle-stage scrollSingle-stage scrollSingle-stage scrollSingle-stage scroll
Supply: V / phase / Hz208/230 / 1 / 60208/230 / 1 / 60208/230 / 1 / 60208/230 / 3 / 60208/230 / 1 / 60208/230 / 1 / 60208/230 / 3 / 60208/230 / 1 / 60208/230 / 1 / 60
Minimum circuit ampacity: A121417172223183031
Maximum overcurrent protection: A152025253535255050
Operating height: in.252525252527393945
Operating length: in.29.7529.7533.7533.7533.7533.7535.7535.7535.75
Operating width: in.29.7529.7533.7533.7533.7533.7535.7535.7535.75
Operating weight: lb141141163186186217244244272
Liquid valve connection O.D.: in.3/83/83/83/83/83/83/83/83/8
Suction valve connection O.D.: in.3/43/43/43/43/47/87/87/87/8

Source: RA13NY specification sheet: model identification p.4, electrical data p.5, operating dimensions p.7. Reviewed November 11, 2026.

  • Use the full model, electrical phase and equipment nameplate. MCA and overcurrent values are manufacturer references; installation and conductor/protection selection must follow the applicable manufacturer instructions and requirements.
  • The listed models are equipment references supported by dated carried-model records, not a live inventory feed. Confirm current availability and contractor pricing before ordering.
  • Three-phase AC1 models use the 208/230 V three-phase electrical block on specification page 5; do not copy the single-phase circuit values. The cited model-identification table includes the complete selected suffixes.

Keep the Northern-region family and the actual rating together.

Ruud identifies RA13NY as a Northern-region air-conditioner family with a 13.4 SEER2 / 9 EER2 family reference. Check the actual listed indoor combination, installation region and current certificate before quoting capacity, efficiency or incentives.

Search by the full outdoor model, then verify every listed component and the current official certificate. A matching brand or nominal size is not an approved system.

Read it. Save it. Bring it to the job.

RA13NY equipment literature

Open the manufacturer reference you need. Documents load when selected.

Search RA13NY references in the Mar-Hy document library

Documents are linked directly and open only when selected. Check the model, revision and complete system scope before applying technical values.

Get a useful quote on the first conversation

Bring the complete cooling-system request.

  1. Full outdoor model, including electrical phase and factory option suffix.
  2. Indoor coil or air-handler model, refrigerant/metering arrangement and required controls.
  3. Cooling load, design conditions, airflow and duct-system requirements.
  4. Cabinet location, service and airflow clearances, piping route and electrical supply.
  5. Required accessories, job schedule and the complete equipment list for contractor pricing.

Selection questions

Does the family efficiency apply to every indoor combination?

Use the current certified record for the exact equipment package. The indoor unit, airflow and controls affect the listed capacity and efficiency.

Does a model listed here mean it is in stock today?

Confirm current sourcing, availability and contractor pricing through the shop or Mar-Hy before committing to the job.

Find it at Mar-Hy

Price the equipment. Plan the whole job.

Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.