Start with a defined zone
Record the room load, heating requirements and proposed indoor location. Use the selected system data rather than assuming nominal size is delivered output.
Call Us: Oregon and SW Washington: (503) 353-0100: Contact Us | Business Hours: 7:00 AM to 5:00 PM Mon-Fri
Daikin / Contractor equipment reference
Compare selected R-32 ENTRA outdoor models and the indoor references listed in the manufacturer brochure, with cabinet dimensions and direct sourcing links.


Plan the equipment around the job
Use the manufacturer-listed indoor/outdoor references and the full installation scope to prepare the equipment package. The table is a model reference, not a complete design.
Record the room load, heating requirements and proposed indoor location. Use the selected system data rather than assuming nominal size is delivered output.
Indoor dimensions change across the listed references. Confirm the installation and service space and include the condensate route in the quote.
Separate these R-32 references from earlier AX-generation equipment and documents. Use the correct instructions and approved accessories for the selected pair.
The numbers contractors need
Compare the listed full models, or select one for a focused view.
3 model references · confirm current sourcing and availability with Mar-Hy.
| Reference | RXC12BVJU912,000 Btu/h class | RXC18BVJU918,000 Btu/h class | RXC24BVJU924,000 Btu/h class |
|---|---|---|---|
| Outdoor model | RXC12BVJU9 | RXC18BVJU9 | RXC24BVJU9 |
| Listed indoor model | FTXC12BVJU9 | FTXC18BVJU9 | FTXC24BVJU9 |
| Model capacity class: Btu/h | 12,000 | 18,000 | 24,000 |
| Refrigerant | R-32 | R-32 | R-32 |
| Outdoor dimensions H × W × D: in. | 21-7/8 × 26-5/8 × 11-1/4 | 29-1/2 × 34-1/4 × 12-5/8 | 29-1/2 × 34-1/4 × 12-5/8 |
| Indoor dimensions H × W × D: in. | 11-1/4 × 30-5/8 × 8-3/4 | 11-1/4 × 30-5/8 × 8-3/4 | 11-5/8 × 39-3/8 × 10-3/8 |
Source: Manufacturer brochure, printed page 10. Reviewed November 11, 2026.
The capacity-class row identifies the model class. It is not a rated-output claim. Confirm the pair’s rated and design-condition capacity, efficiency and applicable AHRI record before using performance figures in a proposal.
Read it. Save it. Bring it to the job.
Open the manufacturer reference you need. Documents load when selected.
Search ENTRA references in the Mar-Hy document library
This manufacturer brochure includes the cited technical table. A separate full-model submittal is not linked in this reference; use the manufacturer selection resources and confirm the exact equipment documents with Mar-Hy.
Get a useful quote on the first conversation
No. Use the complete listed equipment combination and its certified ratings. Do not assign a family maximum to every model or indoor pairing.
These are equipment references. Confirm current contractor pricing, sourcing and availability with Mar-Hy before committing to the job.
Start with the load and application, then use the full model numbers and manufacturer documents to establish the equipment and required accessories.
Find it at Mar-Hy
Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.
RXC12BVJU9
Look up model in the shopConfirm current price and availability in the store.
RXC18BVJU9
Look up model in the shopConfirm current price and availability in the store.
RXC24BVJU9
Look up model in the shopConfirm current price and availability in the store.
Find ENTRA equipment documents
Explore Daikin equipment through Mar-Hy
View Mar-Hy contractor training
Compare Mar-Hy heat-pump families
Prepared for HVAC contractors and trade purchasers. Match the complete model, revision, installation and system combination. This reference is not a live stock feed or a guarantee of design suitability, warranty eligibility or incentive qualification. Follow the applicable manufacturer instructions for the actual equipment.