Skip to main content

Call Us: Oregon and SW Washington: (503) 353-0100: Contact Us | Business Hours: 7:00 AM to 5:00 PM Mon-Fri

Daikin / Contractor equipment reference

Daikin ENTRA Heat Pumps

Compare selected R-32 ENTRA outdoor models and the indoor references listed in the manufacturer brochure, with cabinet dimensions and direct sourcing links.

  • R-32
  • Single-zone wall-mounted
  • Full model pairs below
Daikin ENTRA representative manufacturer product image
Daikin ENTRA representative manufacturer family image. Appearance does not establish an approved equipment combination.

Plan the equipment around the job

Build the single-zone quote around the full RXC / FTXC pair.

Use the manufacturer-listed indoor/outdoor references and the full installation scope to prepare the equipment package. The table is a model reference, not a complete design.

01 / Job fit

Start with a defined zone

Record the room load, heating requirements and proposed indoor location. Use the selected system data rather than assuming nominal size is delivered output.

02 / Indoor unit

Check the actual wall cabinet

Indoor dimensions change across the listed references. Confirm the installation and service space and include the condensate route in the quote.

03 / Full model

Keep the BVJU9 suffix

Separate these R-32 references from earlier AX-generation equipment and documents. Use the correct instructions and approved accessories for the selected pair.

The numbers contractors need

ENTRA model specifications

Compare the listed full models, or select one for a focused view.

3 model references · confirm current sourcing and availability with Mar-Hy.

Daikin ENTRA model specifications
ReferenceRXC12BVJU912,000 Btu/h classRXC18BVJU918,000 Btu/h classRXC24BVJU924,000 Btu/h class
Outdoor modelRXC12BVJU9RXC18BVJU9RXC24BVJU9
Listed indoor modelFTXC12BVJU9FTXC18BVJU9FTXC24BVJU9
Model capacity class: Btu/h12,00018,00024,000
RefrigerantR-32R-32R-32
Outdoor dimensions H × W × D: in.21-7/8 × 26-5/8 × 11-1/429-1/2 × 34-1/4 × 12-5/829-1/2 × 34-1/4 × 12-5/8
Indoor dimensions H × W × D: in.11-1/4 × 30-5/8 × 8-3/411-1/4 × 30-5/8 × 8-3/411-5/8 × 39-3/8 × 10-3/8

Source: Manufacturer brochure, printed page 10. Reviewed November 11, 2026.

  • Use the full model suffix and the cited document revision. Confirm current sourcing with Mar-Hy; these model references are not live availability.
  • The listed equipment does not establish an approved combination by shared capacity alone.
  • Dimensions are transcribed from the cited brochure. Refer to the manufacturer dimensional drawing and installation clearances for the actual model.

Use the rating and heating data for the listed pair.

The capacity-class row identifies the model class. It is not a rated-output claim. Confirm the pair’s rated and design-condition capacity, efficiency and applicable AHRI record before using performance figures in a proposal.

Read it. Save it. Bring it to the job.

ENTRA equipment literature

Open the manufacturer reference you need. Documents load when selected.

Search ENTRA references in the Mar-Hy document library

This manufacturer brochure includes the cited technical table. A separate full-model submittal is not linked in this reference; use the manufacturer selection resources and confirm the exact equipment documents with Mar-Hy.

Get a useful quote on the first conversation

Bring the complete equipment request.

  1. Full outdoor and indoor model numbers, or the existing equipment identification.
  2. Load calculation, heating design conditions and proposed equipment locations.
  3. Available electrical supply, required controls and relevant installation constraints.
  4. Piping route, condensate plan and the accessories needed to complete the work.
  5. Project schedule; request current contractor pricing and availability for the complete package.

Selection questions

Do these models have the same system efficiency?

No. Use the complete listed equipment combination and its certified ratings. Do not assign a family maximum to every model or indoor pairing.

Does a listed model mean it is available now?

These are equipment references. Confirm current contractor pricing, sourcing and availability with Mar-Hy before committing to the job.

Where should I start the selection?

Start with the load and application, then use the full model numbers and manufacturer documents to establish the equipment and required accessories.

Find it at Mar-Hy

Price the equipment. Plan the whole job.

Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.