Size for the room, not the family maximum
Use the room load and the selected pair’s performance data. A family efficiency maximum or model size does not establish the output needed for the job.
Call Us: Oregon and SW Washington: (503) 353-0100: Contact Us | Business Hours: 7:00 AM to 5:00 PM Mon-Fri
Daikin / Contractor equipment reference
Use the current-generation R-32 RXM / FTXM references below to compare listed pairs, cabinet dimensions and the manufacturer specification table.


Plan the equipment around the job
Use the manufacturer-listed indoor/outdoor references and the full installation scope to prepare the equipment package. The table is a model reference, not a complete design.
Use the room load and the selected pair’s performance data. A family efficiency maximum or model size does not establish the output needed for the job.
The larger indoor models use a wider wall cabinet. Confirm wall space, discharge path, service access and the outdoor clearances before committing to the layout.
Earlier RXM/FTXM references also exist. Keep the full model, refrigerant and brochure generation together when ordering or selecting technical data.
The numbers contractors need
Compare the listed full models, or select one for a focused view.
3 model references · confirm current sourcing and availability with Mar-Hy.
| Reference | RXM12WVJU912,000 Btu/h class | RXM18WVJU918,000 Btu/h class | RXM24WVJU924,000 Btu/h class |
|---|---|---|---|
| Outdoor model | RXM12WVJU9 | RXM18WVJU9 | RXM24WVJU9 |
| Listed indoor model | FTXM12WVJU9 | FTXM18WVJU9 | FTXM24WVJU9 |
| Model capacity class: Btu/h | 12,000 | 18,000 | 24,000 |
| Refrigerant | R-32 | R-32 | R-32 |
| Outdoor dimensions H × W × D: in. | 23-7/16 × 33-1/4 × 11-13/16 | 28-15/16 × 34-1/4 × 12-5/8 | 28-15/16 × 34-1/4 × 12-5/8 |
| Indoor dimensions H × W × D: in. | 11-3/4 × 36-1/4 × 10-13/16 | 11-3/4 × 43-5/16 × 10-13/16 | 11-3/4 × 43-5/16 × 10-13/16 |
Source: Manufacturer brochure, printed page 14. Reviewed November 11, 2026.
The capacity-class row identifies the model class. It is not a rated-output claim. Confirm the pair’s rated and design-condition capacity, efficiency and applicable AHRI record before using performance figures in a proposal.
Read it. Save it. Bring it to the job.
Open the manufacturer reference you need. Documents load when selected.
Search ATMOSPHERA references in the Mar-Hy document library
This manufacturer brochure includes the cited technical table. A separate full-model submittal is not linked in this reference; use the manufacturer selection resources and confirm the exact equipment documents with Mar-Hy.
Get a useful quote on the first conversation
No. Use the complete listed equipment combination and its certified ratings. Do not assign a family maximum to every model or indoor pairing.
These are equipment references. Confirm current contractor pricing, sourcing and availability with Mar-Hy before committing to the job.
Start with the load and application, then use the full model numbers and manufacturer documents to establish the equipment and required accessories.
Find it at Mar-Hy
Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.
RXM12WVJU9
Look up model in the shopConfirm current price and availability in the store.
RXM18WVJU9
Look up model in the shopConfirm current price and availability in the store.
RXM24WVJU9
Look up model in the shopConfirm current price and availability in the store.
Find ATMOSPHERA equipment documents
Explore Daikin equipment through Mar-Hy
View Mar-Hy contractor training
Compare Mar-Hy heat-pump families
Prepared for HVAC contractors and trade purchasers. Match the complete model, revision, installation and system combination. This reference is not a live stock feed or a guarantee of design suitability, warranty eligibility or incentive qualification. Follow the applicable manufacturer instructions for the actual equipment.