Ruud / Contractor equipment reference

Ruud RP14AY Heat Pumps

Compare selected single-phase RP14AY models, including the single-stage 1.5-ton exception, and find the documents for a complete ducted-system proposal.

  • R-454B
  • Central split system
  • Single-phase models below
Ruud RP14AY representative manufacturer product image
Ruud RP14AY representative manufacturer family image. Appearance does not establish an approved equipment combination.

Plan the equipment around the job

Build the ducted system around load, airflow and the exact model.

The RP14AY family includes different capacities and electrical configurations. This reference covers the listed 208/230 V single-phase models and keeps the compressor-stage distinction visible.

01 / Staging

Separate the 1.5-ton model from the two-stage models

RP14AY18AJ1NA is the listed single-stage example. The larger AJ2 models shown use the two-stage configuration identified in the manufacturer specification.

02 / Electrical

Keep the voltage and phase suffix

A capacity prefix does not identify the electrical version. Use the full AJ model below; do not transfer these single-phase electrical values to AC or AD variants.

03 / Indoor side

Check the coil, airflow and controls

Document the selected indoor equipment and the airflow/control requirements. Confirm the applicable combination and manufacturer installation scope before quoting.

The numbers contractors need

RP14AY model specifications

Compare the listed full models, or select one for a focused view.

5 model references · confirm current sourcing and availability with Mar-Hy.

Ruud RP14AY model specifications
ReferenceRP14AY18AJ1NA1.5-ton nominalRP14AY24AJ2NA2-ton nominalRP14AY36AJ2NA3-ton nominalRP14AY48AJ2NA4-ton nominalRP14AY60AJ2NA5-ton nominal
Outdoor modelRP14AY18AJ1NARP14AY24AJ2NARP14AY36AJ2NARP14AY48AJ2NARP14AY60AJ2NA
Nominal tonnage1.52345
Compressor stages12222
RefrigerantR-454BR-454BR-454BR-454BR-454B
Power: V / phase / Hz208/230 / 1 / 60208/230 / 1 / 60208/230 / 1 / 60208/230 / 1 / 60208/230 / 1 / 60
Minimum circuit ampacity: A1316202733
Maximum overcurrent protection: A2025304550
Liquid connection: in.3/83/83/83/83/8
Suction connection: in.3/43/43/47/87/8

Source: RP14AY P22-840 Rev. 1, printed pages 3–5. Reviewed November 11, 2026.

  • Use the full model suffix and the cited document revision. Confirm current sourcing with Mar-Hy; these model references are not live availability.
  • The listed equipment does not establish an approved combination by shared capacity alone.
  • Only selected single-phase models are tabulated; the manufacturer offers additional capacities and electrical versions. Confirm the exact source column and full suffix.
  • Use the nameplate and applicable manufacturer/electrical requirements for the installed equipment.

Rate the complete equipment combination.

Use the actual indoor and outdoor combination and the applicable manufacturer performance data. Nominal model size does not establish capacity at the project’s design conditions or incentive eligibility.

Read it. Save it. Bring it to the job.

RP14AY equipment literature

Open the manufacturer reference you need. Documents load when selected.

Search RP14AY references in the Mar-Hy document library

Check the full model, revision and system scope before using technical information. Open the selected document when needed.

Get a useful quote on the first conversation

Bring the complete equipment request.

  1. Full outdoor and indoor model numbers, or the existing equipment identification.
  2. Load calculation, heating design conditions and proposed equipment locations.
  3. Available electrical supply, required controls and relevant installation constraints.
  4. Piping route, condensate plan and the accessories needed to complete the work.
  5. Project schedule; request current contractor pricing and availability for the complete package.

Selection questions

Do these models have the same system efficiency?

No. Use the complete listed equipment combination and its certified ratings. Do not assign a family maximum to every model or indoor pairing.

Does a listed model mean it is available now?

These are equipment references. Confirm current contractor pricing, sourcing and availability with Mar-Hy before committing to the job.

Where should I start the selection?

Start with the load and application, then use the full model numbers and manufacturer documents to establish the equipment and required accessories.

Find it at Mar-Hy

Price the equipment. Plan the whole job.

Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.