What a Refrigerant’s GWP Number Does and Does Not Tell You

Originally published September 10, 2025
Updated November 5, 2026 3 min read

A lower refrigerant GWP is a specific environmental characteristic. It is not an efficiency rating, a safety classification, or approval to substitute that refrigerant into existing equipment. Understanding the number helps contractors explain a product accurately and compare claims on the same basis.

GWP compares the effect of emissions by mass

EPA defines global warming potential as a comparison of the warming effect of an emitted gas with the same mass of carbon dioxide over a stated period. The commonly used period is 100 years, and carbon dioxide is the reference with a GWP of one.

The time period and assessment basis matter. EPA notes that different reporting programs can use different scientific assessment values. Record the source of the number before comparing two published claims.

For example, a value taken from one assessment should not silently be compared with another refrigerant’s value from a different basis if the purpose is a consistent technical or regulatory comparison.

Use a hypothetical example carefully

Suppose Gas A has a GWP of 2,000 and Gas B a GWP of 450 on the same basis. These are hypothetical values for arithmetic, not product specifications. For equal emitted mass, B’s GWP is 77.5% lower: (2,000 − 450) ÷ 2,000 × 100.

If two kilograms of each gas were emitted, the illustrative carbon-dioxide-equivalent amounts would be 4,000 kilograms for A and 900 kilograms for B. The calculation multiplies emitted mass by the GWP factor.

Notice the words “if emitted.” A system’s charge is not automatically its annual emission. The example does not predict leaks, operating energy, or the complete environmental impact of either system.

Keep GWP separate from energy performance

GWP describes the gas-emissions comparison. Seasonal efficiency ratings and equipment performance data describe different properties. A percentage reduction in GWP cannot be copied into a utility-bill savings statement.

For an operating-cost comparison, establish the selected equipment combination, building load, climate, controls, energy rates, and use assumptions. Compare equivalent service, and label a modeled result as an estimate.

Two systems using the same refrigerant can still have different capacities, modulation ranges, applications, and performance. Refrigerant identity is one input to selection, not a replacement for the selection process.

Keep the safety classification separate too

A low-GWP label does not identify every handling hazard. Use the specified refrigerant’s safety information and the equipment’s applicable instructions. Carrier’s refrigerant comparison, for example, distinguishes R-410A’s A1 classification from R-454B’s A2L classification and says R-454B is not a drop-in replacement.

Do not infer suitable tools, procedures, components, or task qualifications from GWP alone. Those need their own documented checks for the exact work.

When explaining a replacement to a customer, describe the selected system and why it fits the application. Avoid presenting the refrigerant name as proof of safety, savings, or universal compatibility.

Read the scope of a regulatory GWP limit

A rule may use a specified GWP basis and threshold for a defined equipment category and activity. The number alone does not tell you whether the rule concerns manufacturing, installation, service, or another action.

Use EPA’s current Technology Transitions material for the relevant regulatory question, including later amendments. A broad “GWP under 700” note is not enough to release every HVAC order.

Questions to keep distinct in a refrigerant comparison
ClaimEvidence needed
Lower GWPGas identity, value, time horizon, and consistent assessment basis.
Lower energy useRelevant system performance and application assumptions or measured results.
Suitable for the equipmentManufacturer-supported application and applicable instructions.
Meets a particular ruleCurrent provision, equipment category, activity, dates, and qualified review.

For product selection at Mar-Hy, bring the application and full proposed equipment combination. Use the refrigerant’s GWP as a precise fact within that discussion, with its basis clear.

PROSTOCK AT MAR-HY

PROSTOCK PROFESSIONAL QUALITY HVAC PARTS AND SUPPLIES

Mar-Hy Prostock HVAC parts and supplies store in Milwaukie

Support for the next service call.

Mar-Hy Distributors adopted the Prostock concept to enhance our support of local HVAC contractors. Since opening our Prostock store, we have received positive feedback from contractors on how they have improved response time to their customers. Our HVAC contractors have been able to stay ahead of the competition with access to our extensive inventory of Prostock Parts.

Quality parts. Contractor support.

Our Prostock replacement parts department is committed to improving the business of our HVAC contractors by providing quality services, competitive pricing, and products and supplies that earn customer trust and build lifetime customer satisfaction. We value our contractors and will continue to provide top of the line service for all of your HVAC needs.