Skip to main content

Call Us: Oregon and SW Washington: (503) 353-0100: Contact Us | Business Hours: 7:00 AM to 5:00 PM Mon-Fri

Installation & service / MAR-HY ARTICLES

Investigate HVAC Energy Use Before Promising a Saving

Originally published February 15, 2025
Updated November 5, 2026 4 min read

A higher utility bill can come from more energy use, a different rate, colder or hotter weather, changed occupancy, or an equipment problem. Start by separating those possibilities. A useful efficiency recommendation explains which problem it addresses and how the result will be evaluated.

Separate the bill from the energy quantity

A bill is a financial result. Kilowatt-hours, therms, and other energy units describe consumption. Rates, fixed charges, demand charges, and billing-period length can change the relationship between the two.

In an invented electricity example, 1,000 kWh at $0.15 per kWh costs $150 before other charges. A later period uses 900 kWh at $0.18 per kWh, costing $162 on the same simplified basis. Consumption falls 10% while the modeled energy charge rises 8%.

The example does not describe a local tariff. It shows why a larger bill is not proof that the HVAC system used more energy. Obtain the actual rate and billing details before calculating a customer-specific financial effect.

Establish what changed in the building

Compare the periods, weather, occupied hours, setpoints, activities, and equipment serving the space. A new tenant schedule or added room can change the load even when the system is functioning as designed.

Also identify changes in the building itself. Openings, shading, air leakage, insulation, and internal heat sources affect the heating or cooling the equipment must provide. Replacing equipment does not remove an unrelated building-load problem.

DOE’s measurement and verification overview describes methods that compare performance with a baseline and address relevant operating factors. Its federal-project procedures are not a universal requirement for a home service call, but they illustrate why an unadjusted before-and-after bill comparison has limits.

Understand how maintenance can affect performance

The ENERGY STAR maintenance checklist identifies filters, coils, airflow, controls, and other equipment-specific checks. Dirty coils can interfere with heat transfer, and airflow problems can affect the system’s ability to deliver the intended heating or cooling.

The mechanism matters. Air must pass through the intended path and exchange heat with the equipment. A restriction, fouling, or control problem can interfere with that process. The actual effect depends on the system and condition; a generic maintenance percentage is not a measured saving for this customer.

Use qualified personnel and applicable manufacturer instructions for diagnosis and corrective work. Maintenance is not a reason to add refrigerant on a calendar schedule or change a setting without evidence. Record what was found and the verified correction rather than promise that every tune-up produces the same result.

Distinguish efficient equipment from efficient operation

A rating describes performance under the applicable test framework and specified combination. Actual installed performance also depends on selection, installation, controls, distribution, load, and use. A high rating does not by itself establish a particular utility bill.

Likewise, a smart thermostat provides supported control functions, but savings depend on the previous and new operation. A schedule that already matches the building’s needs may leave less opportunity than an inappropriate schedule. Some systems require particular control strategies or restrictions.

Have the responsible designer or technician review changes against comfort, moisture, ventilation, equipment, and occupant requirements. Reducing runtime by failing to meet the required service is not an equivalent efficiency improvement.

Compare options on the same service basis

Suggested efficiency comparison
OptionWhat it may addressWhat must be established
Correct a verified faultPerformance lost through a specific equipment or installation problem.Diagnosis, suitable correction, and verification.
Adjust supported controlsOperation that does not match the actual building schedule or need.Required service, compatible strategy, and authorization.
Improve the buildingA defined load or distribution issue outside the equipment.Qualified assessment and coordinated scope.
Replace equipmentA supported replacement need with a suitable system.Load, capacity, match, installation scope, and comparison assumptions.

Do not add savings percentages as independent promises

Two proposed measures can interact because they act on the same remaining energy use. In an abstract example, begin with 1,000 units of energy. If one measure reduces that modeled quantity by 10%, 900 units remain. A second 10% reduction applied to the remainder gives 810 units, a total reduction of 19%, not 20%.

This arithmetic is not a prediction for any HVAC measure. Actual interactions can be more complicated: a building-load change can affect equipment sizing, a controls change can affect operating hours, and maintenance can change the baseline against which a replacement is compared.

Ask the person preparing the analysis how combined measures are represented. Avoid adding unrelated brochure percentages and applying the total to the customer’s entire utility bill. Identify the energy uses affected, the baseline, and the sequence of the comparison.

When results are uncertain, show a reasonable range supported by the analysis rather than a precise-looking dollar figure without a defensible basis. Explain which future rates and operating assumptions could change the outcome.

Report the expected and observed results separately

A proposal may contain an estimate based on assumptions; a later report may contain measured observations. Label each clearly. Explain what costs, weather conditions, and operating changes are included and what remains uncertain.

Bring the exact system and job requirements to Mar-Hy when comparing replacement equipment or required materials. Use the resulting documentation as one input to the complete application and energy review.

PROSTOCK AT MAR-HY

PROSTOCK PROFESSIONAL QUALITY HVAC PARTS AND SUPPLIES

Mar-Hy Prostock HVAC parts and supplies store in Milwaukie

Support for the next service call.

Mar-Hy Distributors adopted the Prostock concept to enhance our support of local HVAC contractors. Since opening our Prostock store, we have received positive feedback from contractors on how they have improved response time to their customers. Our HVAC contractors have been able to stay ahead of the competition with access to our extensive inventory of Prostock Parts.

Quality parts. Contractor support.

Our Prostock replacement parts department is committed to improving the business of our HVAC contractors by providing quality services, competitive pricing, and products and supplies that earn customer trust and build lifetime customer satisfaction. We value our contractors and will continue to provide top of the line service for all of your HVAC needs.