Read every part of the code
AMHE3D10B2N1 identifies the ECM blower, size-3 platform, downflow configuration, nominal 10 kW heat option, breaker connection, 208/240 V supply code and no included coil cabinet. Keep that complete identity on the order.
Call Us: Oregon and SW Washington: (503) 353-0100: Contact Us | Business Hours: 7:00 AM to 5:00 PM Mon-Fri
ADP / Contractor equipment reference
Plan the manufactured-home furnace, coil cabinet and electric-heat requirements as separate selections. Start with the confirmed AMHE3D10B2N1 reference below.


Plan the equipment around the job
The mFurnace is an electric-furnace and blower platform for manufactured-home applications. Its unit-size code, electric-heat option and separate coil cabinet answer different selection questions; none should be inferred from the overall product photo.
AMHE3D10B2N1 identifies the ECM blower, size-3 platform, downflow configuration, nominal 10 kW heat option, breaker connection, 208/240 V supply code and no included coil cabinet. Keep that complete identity on the order.
The furnace cabinet and an MH-series coil cabinet have separate dimensions and model numbers. Choose the cabinet and evaporator coil for the actual installation rather than treating MHCDLS23 or a similar cabinet reference as the furnace model.
Published nominal airflow is not the delivered airflow at every speed and static pressure. Electric-heat output and electrical values also change with supply voltage. Use the matching tables for the selected configuration.
The numbers contractors need
Full-model reference for the confirmed furnace configuration.
1 model reference · confirm current sourcing and availability with Mar-Hy.
| Reference | AMHE3D10B2N1Size-3 ECM · nominal 10 kW at 240 V |
|---|---|
| Full furnace model | AMHE3D10B2N1 |
| Application | Manufactured-home electric furnace |
| Unit-size code | 3 · size-3 blower platform |
| Blower motor | 5-speed ECM |
| Factory configuration | Downflow; field-conversion requirements apply |
| Supply-voltage code | 208/240 V · 1 phase · 60 Hz |
| Electric-heat code | 10 · nominal 10 kW at 240 V |
| Line-voltage connection code | B · circuit breaker |
| Coil-cabinet code | N · cabinet not included |
| Furnace H × W × D (in.) | 33.0 × 19.8 × 23.4 — specification drawing |
| Nominal family airflow reference (CFM) | 900–1,100; actual airflow depends on tap and static |
| Transformer reference | 40 VA · Class 2 |
Source: ADP SG-AMAH-01-02 — pages 2, 4, 6 and 9. Reviewed November 10, 2026.
For the size-3 platform with the 10 kW heat option, the cited specification provides different electrical values at 208 V and 240 V. These are manufacturer table references, not a branch-circuit design. Verify the actual nameplate, heater configuration, supplied breaker and applicable instructions before installation.
| Reference condition | 208 V | 240 V |
|---|---|---|
| Nominal heat at stated voltage (kW) | 7.51 — source correction factor applied | 10.0 |
| Total current in source table (A) | 40.0 | 45.6 |
| Minimum circuit ampacity in source table (A) | 50.0 | 57.0 |
| Maximum circuit breaker in source table (A) | 50 | 60 |
For a heat-pump or cooling-system rating, search the complete outdoor-unit and coil combination. The furnace’s electric-heat and blower data do not establish an AHRI system rating.
Read it. Save it. Bring it to the job.
Open the manufacturer reference you need. Documents load when selected.
Search mFurnace references in the Mar-Hy document library
The manufacturer’s submittal link returns an Excel workbook, so it is identified as XLSX here. Ask Mar-Hy for the applicable warranty terms, registration requirements and the complete coil-cabinet package for the job.
Get a useful quote on the first conversation
No. The N cabinet code identifies no included coil cabinet. Select the cabinet and evaporator coil separately for the actual installation; the family photo illustrates one assembled arrangement.
No. The manufacturer rates that option at 240 V and gives a 0.751 output correction factor for 208 V. Use the voltage-specific electrical table and the actual equipment nameplate.
No. Confirm required airflow and the actual blower configuration, coil and outdoor equipment. Use the complete approved combination to establish cooling/heating capacity and system ratings.
Find it at Mar-Hy
Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.
AMHE3D10B2N1
Look up model in the shopConfirm current price and availability in the store.
Find mFurnace equipment documents
Browse ADP manufacturer literature
View Mar-Hy contractor training
Prepared for HVAC contractors and trade purchasers. Match the complete model, revision, installation and system combination. This reference is not a live stock feed or a guarantee of design suitability, warranty eligibility or incentive qualification. Follow the applicable manufacturer instructions for the actual equipment.