Daikin / Contractor equipment reference

Daikin MXM Multi-Zone Heat Pumps

Plan a multi-room R-32 system with outdoor-unit specifications, indoor-combination guidance and manufacturer literature in one contractor reference.

  • R-32
  • 2–4-port models below
  • Inverter-driven
Daikin MXM R-32 representative manufacturer product image
Daikin MXM manufacturer family image. Use the complete outdoor model and approved indoor combination; cabinet appearance is not a system selection.

Plan the equipment around the job

Choose the zones before choosing the outdoor unit.

An MXM proposal starts with each room’s load, the indoor-unit styles and the way those rooms will be used. Outdoor nominal size is one part of the selection—not a promise of full capacity at every indoor unit simultaneously.

01 / Indoor combinations

Specify every room and every head

Record the complete indoor model for each zone. Wall mounts, concealed units and other styles must be checked against the combination tables for the selected outdoor model; a shared brand or refrigerant does not approve a pairing.

02 / Connected capacity

Compare demand, not just nameplates

Use the manufacturer’s allowed combinations and corrected performance data. Adding indoor nameplate capacities does not establish the capacity available to a particular room when several zones call together.

03 / Installation planning

Bring the full piping route

Total piping length, each room’s branch length and vertical separation are different limits. Document the proposed route and required controls before quoting the equipment and installation accessories.

The numbers contractors need

MXM R-32 model specifications

Compare the listed full models, or select one for a focused view.

3 model references · confirm current sourcing and availability with Mar-Hy.

Daikin MXM R-32 model specifications
Reference2MXM18AVJU918,000 Btu/h class · 2 ports3MXM24AVJU924,000 Btu/h class · 3 ports4MXM36AVJU936,000 Btu/h class · 4 ports
Outdoor model2MXM18AVJU93MXM24AVJU94MXM36AVJU9
Nominal size class (Btu/h)18,00024,00036,000
Maximum indoor connections234
RefrigerantR-32R-32R-32
Power supply208–230 V · 1 phase · 60 Hz208–230 V · 1 phase · 60 Hz208–230 V · 1 phase · 60 Hz
CompressorInverter-driven swingInverter-driven swingInverter-driven swing
Cabinet H × W × D (in.)29-1/2 × 34-1/4 × 12-5/829-1/2 × 34-1/4 × 12-5/829-1/2 × 34-1/4 × 12-5/8
Net weight (lb)127140142
Minimum circuit ampacity (A)15.619.924.1
Maximum overcurrent protection (A)202525
Sound pressure — cooling / heating (dBA)52 / 5452 / 5456 / 60
Liquid connection O.D. (in.)1/4 × 2 ports1/4 × 3 ports1/4 × 4 ports
Gas connection O.D. (in.)3/8 × 1; 1/2 × 13/8 × 1; 1/2 × 23/8 × 1; 1/2 × 2; 5/8 × 1

Source: Daikin EDUS122402 — printed pages 9–10 and 32 (PDF pages 11–12 and 34). Reviewed November 10, 2026.

  • These values cover the listed AVJU9 models. They do not establish AVJU8 or five-zone 5MXM48 specifications.
  • Nominal size and port count are selection identifiers. Confirm connected indoor capacity, corrected capacity and operating limits for the complete job.
  • Cabinet dimensions are not installation clearances. Port sizes do not replace the manufacturer’s branch-piping and adapter requirements.
  • Confirm electrical data against the unit nameplate and applicable installation instructions before designing the circuit.

Match the indoor units before putting efficiency on the proposal.

The published MXM family reaches up to 21 SEER2 and 10 HSPF2 in qualifying combinations. The actual rated combination, indoor-unit arrangement and application determine which figures apply. Select the complete outdoor and indoor models in the AHRI finder, then verify the official record. Design-temperature capacity still requires the manufacturer’s performance data.

Read it. Save it. Bring it to the job.

MXM R-32 equipment literature

Open the manufacturer reference you need. Documents load when selected.

Search MXM R-32 references in the Mar-Hy document library

The engineering manual is a technical reference, not a dedicated model submittal. Its stated scope covers the 2/3/4MXM-A models shown here; five-zone literature remains separate.

Get a useful quote on the first conversation

Build the complete multi-zone quote.

  1. Room-by-room loads, design temperatures and intended use of each zone.
  2. Full outdoor model and every indoor-unit model, including style and capacity.
  3. Total piping, individual branch lengths, elevations and planned equipment locations.
  4. Electrical supply, control strategy, drainage and required installation accessories.
  5. The rated combination and the documents needed for the proposal and startup.

Selection questions

Does a four-port outdoor unit approve any four indoor units?

No. Port count is only the connection limit. Confirm the manufacturer’s indoor-model combinations and connected-capacity rules, then establish the capacity available for the actual operating conditions.

Does the chart cover five-zone MXM equipment?

No. The engineering reference used for this chart covers the listed two-, three- and four-port models. Use the separate manufacturer instructions and specifications for 5MXM48 equipment.

What should be included in the price comparison?

Compare the complete indoor/outdoor combination, controls, drainage, mounting and piping accessories, delivery needs and installation scope. Ask Mar-Hy for current contractor pricing and availability; this page is not a live stock feed.

Find it at Mar-Hy

Price the equipment. Plan the whole job.

Use the model lookup below, or ask our team to confirm sourcing, current contractor pricing and availability. Mar-Hy serves contractors in Oregon and Southwest Washington from Milwaukie.

36,000 Btu/h class · 4 ports

4MXM36AVJU9

Ask about model sourcing

Manufacturer family reference; confirm sourcing with Mar-Hy.